Volar Radius Plate: Advanced Fracture Fixation System for Optimal Wrist Recovery

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

volar radius plate

The volar radius plate is a sophisticated orthopedic implant designed specifically for treating distal radius fractures through a volar approach. This innovative medical device provides stable internal fixation for various fracture patterns while enabling anatomical reconstruction of the articular surface. The plate features multiple screw holes strategically positioned to offer optimal fixation options, accommodating different fracture patterns and patient anatomies. Its low-profile design minimizes soft tissue irritation while maintaining structural integrity. The plate is constructed from high-grade medical titanium or stainless steel, ensuring biocompatibility and long-term durability. Advanced manufacturing techniques create a contoured shape that matches the volar surface of the distal radius, facilitating easier placement and better anatomical fit. The plate system includes both fixed-angle and variable-angle locking options, providing surgeons with flexibility in screw placement and enhanced stability for fracture fixation. This versatility makes it suitable for both simple and complex fracture patterns, including intra-articular fractures. The design incorporates features to prevent screw back-out and includes targeting guides for precise screw placement. Its rounded edges and polished surface help reduce the risk of tendon irritation and other soft tissue complications.

New Products

The volar radius plate offers numerous significant advantages in treating distal radius fractures. First, its anatomically contoured design ensures an excellent fit to the bone surface, reducing the need for intraoperative bending and minimizing operative time. The low-profile construction significantly decreases soft tissue irritation while maintaining robust mechanical strength. The plate's multiple locking options provide enhanced stability, particularly beneficial in osteoporotic bone, where traditional screws might not achieve adequate fixation. The variable-angle technology allows surgeons to address specific fracture patterns with greater precision, optimizing screw placement for maximum stability. The system's comprehensive range of sizes accommodates different patient anatomies, ensuring appropriate coverage for various fracture patterns. The plate's design facilitates early mobilization, which is crucial for better functional outcomes and faster recovery. Its titanium composition offers excellent biocompatibility while providing the necessary strength for fracture support. The surgical technique is straightforward, with well-designed instrumentation that aids in accurate placement and reduces operating time. The plate's stability allows for immediate post-operative hand movement, promoting better functional outcomes and patient satisfaction. Long-term clinical studies have demonstrated reliable fusion rates and minimal complications, making it a trusted choice among orthopedic surgeons.

Latest News

Multi scenario application analysis: flexible advantages of modular braces in trauma and orthodontics

09

May

Multi scenario application analysis: flexible advantages of modular braces in trauma and orthodontics

View More
Application scenarios of unilateral stent in limb fractures

09

May

Application scenarios of unilateral stent in limb fractures

View More
Taylor Space Bracket: Application of 3D Orthopedic Technology in Complex Malformation Correction

09

May

Taylor Space Bracket: Application of 3D Orthopedic Technology in Complex Malformation Correction

View More
Minimally invasive priority: innovation of internal fixation technology in pediatric orthopedic surgery

09

May

Minimally invasive priority: innovation of internal fixation technology in pediatric orthopedic surgery

View More

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

volar radius plate

Advanced Locking Mechanism Technology

Advanced Locking Mechanism Technology

The volar radius plate incorporates state-of-the-art locking mechanism technology that represents a significant advancement in fracture fixation. This system features both fixed and variable-angle locking options, providing unprecedented flexibility in screw placement. The variable-angle technology allows screws to be placed within a 15-degree cone of angulation, enabling surgeons to optimize screw trajectory based on individual fracture patterns. The threading design ensures secure locking while preventing cross-threading, significantly reducing the risk of hardware failure. This advanced locking mechanism creates a stable fixed-angle construct that maintains reduction and promotes proper healing, particularly crucial in osteoporotic bone. The system's ability to combine conventional, fixed-angle, and variable-angle screws in a single plate provides maximum versatility for complex fracture patterns.
Anatomical Design Excellence

Anatomical Design Excellence

The anatomical design of the volar radius plate represents a perfect balance between form and function. The plate's contour precisely matches the volar surface of the distal radius, resulting from extensive anatomical studies and computer-aided design. This precise matching reduces the need for intraoperative contouring and ensures optimal bone contact. The plate features a graduated thickness, being thinner distally to minimize tendon irritation while maintaining thickness proximally for strength. Strategic placement of screw holes allows for optimal fragment fixation while avoiding critical anatomical structures. The design includes specific features to support the subchondral bone and maintain articular reduction, crucial for preserving joint function.
Enhanced Surgical Workflow Integration

Enhanced Surgical Workflow Integration

The volar radius plate system includes comprehensive instrumentation designed to streamline the surgical workflow and enhance precision. The targeting guides are specifically engineered for accurate screw placement, reducing fluoroscopy time and improving operating room efficiency. The system includes depth gauges, drill guides, and specialized instruments that work seamlessly together to facilitate precise implant positioning. Color-coded instruments and implants simplify size selection and reduce the potential for errors. The plate's design allows for easy identification of screw hole direction and type, making the surgical procedure more intuitive. The system's comprehensive set of instruments supports both standard and minimally invasive surgical techniques, providing flexibility in surgical approach based on specific case requirements.
logo